User manual
ADA-13040MG
ETHERNET to RS485/RS422 Converter
with MODBUS GATEWAY
1
io_ada-13040MG_en_v1.12
ADA-13040MG
Copyright © 2001-2014 CEL-MAR sp.j.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - User manual

User manualADA-13040MGETHERNET to RS485/RS422 Converterwith MODBUS GATEWAY1io_ada-13040MG_en_v1.12ADA-13040MGCopyright © 2001-2014 CEL-MAR sp.j.

Pagina 2

3.3. RS485/RS422 BUS CONNECTIONThe RS485/RS422 interface is available in the ADA-13040MG on screw terminal block, labelled as: Tx+/A, Tx-/B, Rx+, Rx-.

Pagina 3

Fig. 11. Example connection of the RS485(2W) devices to ADA-13040MG3.3.4. LINE TERMINATION Rt of RS485 BUSThe application of Line Termination (termina

Pagina 4

5.2. INITIAL CONFIGURATION USING ADAFINDER SOFTWARE5.2.1. ADAFINDER INSTALLATIONThe initial configuration of network setting at the converter can be m

Pagina 5

Fig. 13. ADAFinder configuration of IP network address5.3. CONFIGURATION AND MANAGEMENT BY THE USE OF INTERNET BROWSERIntegrated WWW server to ADA-130

Pagina 6

5.3.1. NETWORK CONFIGURATIONTo make a changes of default setting or new configuration of ADA-13040MG, select on left panel Configuration -> Network

Pagina 7

Fig. 16. Selection serial port profile web5.3.2.1.1. REALPORT (VIRTUAL PORT ) CONFIGURATIONChoosing RealPort (Virtual Port, Fig. 16) is configured the

Pagina 8

Fig. 17. Example configuration of TCP serverFor configuration of TCP Client Settings (Fig 18), select Automatically establish TCP connections, connect

Pagina 9

5.3.2.1.2.3. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATIONFor proper operation of ADA-13040MG with device connected to his RS485/RS422 serial por

Pagina 10 - ADA-13040MG

5.3.2.1.3.2. UDP CLIENT & SERVER CONFIGURATION IN CASE OF SLAVE DEVICESet operating parameters of UDP server for SLAVE device connected via seria

Pagina 11

5.3.2.1.3.3. SERIAL PORT TRANSMISSION PARAMETERSFor proper operation of ADA-13040MG with device connected to his RS485/RS422 serial port, should be se

Pagina 12

Contents1. GENERAL INFORMATION...

Pagina 13

Fig. 22. Example configuration for communication with MODBUS-MASTER devices – choice of devices and protocolsSet the options in section Modbus RTU

Pagina 14

Fig. 25. Example configuration for communication with MODBUS-MASTER devices – table entry configuration for SLAVE type devicesOn section Advanced Prot

Pagina 15

Fig. 27. Example configuration for communication with MODBUS-SLAVE devices – choice of devices and protocolsSet options in section [Modbus RTU Settin

Pagina 16

ATTENTION !Default port of Industrial Automation (Modbus Gateway) service is 502.If on the local network is conflict with other network service using

Pagina 17

C/ User Permissions - user permissions to configuration and management of the ADA-13040MG converter, where are an options:None - no permission,Read -

Pagina 18

6. USING VIRTUAL PORT SERVICE [REALPORT] 6.1. VIRTUAL PORT DRIVER INSTALLATION IN WINDOWS XPThe installation of virtual serial port drivers should be

Pagina 19

Fig. 31. Devices view on Windows XPFig. 32. Example configuration of multi-port serial adapter 26ADA-13040MG

Pagina 20

7. FACTORY DEFAULTParameter ValueUser name rootPassword dbpsIP address Obtain an IP address automatically using DHCPOperating mode RealPortBout rate[b

Pagina 21

Transmission line4-pair twisted cable, UTP 4x2x0,5 (24AWG), shield inside large interferences STP 4x2x0,5 (24AWG)).1-2-pair twisted cable, eg. UTP 1x2

Pagina 22

6. USING VIRTUAL PORT SERVICE [REALPORT] ...

Pagina 23

1. GENERAL INFORMATIONThank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by two year warra

Pagina 24

• Power supply 10 - 30 VDC stable min. 3W,• ~ 3000V= optoizolation in signal channel between ETHERNET and RS485/RS422 interface,• 1000V= or 3000V= gal

Pagina 25

2.3.3. COMMUNICATIONS IN THE SERIAL BRIDGE MODECommunication in the serial bridge mode allows to transfer data via Ethernet network between serial por

Pagina 26

In the modular socket ETHERNET interface of converter, are implemented two LED's (Fig. 2):– Green ACT signaling state of sending or receiving dat

Pagina 27

Fig. 5. The WAN connection to operating in the Real Port mode3.2.3. CONNECTION FOR OPERATING IN TCP & UDP SERIAL BRIDGE MODEFig. 6, 7 below show h

Pagina 28

Fig. 7. The LAN connection to operating in the UDP serial bridge mode, one-to-many3.2.4. CONVERTERS CONNECTION AS MODBUS GATEWAYFigure 8 shows connect